The airtight doors by BUCHELE are certified in accordance with DIN 1026 and are classified in accordance with DIN EN 12207 in different so called air permeability classifications. The test is to determine how many m³ of air gets into a room within an hour starting from a low breeze up to a hurricane. Special four-sided seals reduce penetrating air masses. For special high demands the contact pressure may be increased with additional locking mechanisms.
Technical data sheets
Air Tight Doors with Fire Protection
SINGLE LEAF
EI230
EI260
EI290
DOUBLE LEAF
EI230
EI260
EI290
Flush Allround-Talents
One door series, but a thousand possibilities. The PLANE-Line-Doors are the all-round talents by BUCHELE. Each door is planned and manufactured individually. Therefore, the door may be equipped with various features: Sound insulation, fire protection, burglar resistant, bullet resistant, if required even in various combinations.
The PLANE-Line-Doors are available in three versions: BASIC, PREMIUM and SUPERIOR.
Technical data sheets
SINGLE LEAF
DOUBLE LEAF
PLANE Line
BASIC •
Version with 3-sided frame and three-parted, height-adjustable construction hinges with ball-bearing spacer ring. (If designed as fire protection door with additional standard arm door-closer.)
PREMIUM ••
Version with 3-sided PLANE Line special frame for flush mounted optics on hinge side, three-dimensional adjustable object hinges. (If designed as fire protection door with additional slide channel door closer system.)
SUPERIOR •••
Version with 3-sided PLANE Line special frame for flush mounted optics on hinge side, concealed, three-dimensional adjustable hinge system (If designed as fire protection door with additional, concealed slide channel door closer system.)
Sliding-gates for critical environments
Safety can be done large – with gates by BUCHELE. The sliding and folding gates offer high protection classifications and may, therefore, be used in critical environments.
By the way: It is no longer only government agencies that rely on this high safety quality. More and more private individuals want to play it safe. They are also our customers.
Technical data sheets
What are the safety classes RC2 to RC5??
Radiation protection
Radiation protection doors are used were people or animals have to be protected against x-ray, gamma or electron radiation. Therefore, those doors mainly find their application in medical and research areas. BUCHELE-radiation protection doors are designed and manufactured in accordance with DIN 6834. As performance characteristics the lead equivalent value is expressed in mm.
By the way: BUCHELE-radiation protection doors may also be equipped with radiation protection glazing (optional also with integrated electrically operated privacy screens).
High-Frequency-Shielding doors for ENS, EMI and EMC
Increasing electromagnetic emissions require the use of shielding measures for instance against lightning discharge (LEMP), interaction of devices (EMC) or disturbances and health impairment due to electrosmog caused by radar, transmission masts and power supply lines. For this reason BUCHELE shielding doors are certified in accordance with IEEE 299 and work in a frequency range between 10 kHz and 10 GHz. This is achieved due to a patented HF-sealing system in connection with a barrier-free hump threshold. The BUCHELE-shielding doors may also be combined with other features such as fire protection, sound protection and property protection.
Technical data sheets
High Frequency Shielding Doors (EMS, EMI, EMV)
SINGLE LEAF
DOUBLE LEAF
Radiation Protection Doors
SINGLE LEAF
DOUBLE LEAF
Special doors by the specialist
When storing hazardous substances there are strict requirements on safety. There, particular attention is paid to the personnel that are within the danger zone. BUCHELE-doors on one hand reduce the risk of an explosion on the other hand the doors withstand a pressure load in an emergency situation. Depending on the amount and type of stored substances each pressure proof door is uniquely designed, calculated and manufactured according to customer’s requirements. In order to absorb the enormous forces special locking systems are used. These systems are specially developed and manufactured by BUCHELE.
Technical data sheets
SINGLE LEAF
DOUBLE LEAF
Doors & windows
Natural forces such as storm and floods become more and more extreme. The flood protection doors and windows by BUCHELE are designed for this purpose. Underground garages, appartment buildings, industrial buildings: the use is versatile.
INSPECTION: No flood protection element, door or window, leaves our premises without being inspected on function and impermeability. BUCHELE has established a special test stand to check these elements. After passing the tests the elements receive a label and a test report.
Technical data sheets
Flood Protection Doors
Sliding Gate
Fixed Glazing
Window
Technical data sheets
Burglar Proof Ventilation Grilles
Burglar Proof Grilles
What are the safety classes RC2 to RC5?
» Overview of the safety classes
Safety can be done large – with gates by BUCHELE.
The sliding and folding gates offer high protection classifications and may, therefore, be used in critical environments.
By the way: It is no longer only government agencies that rely on this high safety quality. More and more private individuals want to play it safe. They are also our customers.
Burglar Proof Folding Doors
One- and two-wing-safety-doors
The safety doors by BUCHELE are certified in accordance with DIN EN 1627 – and provide depending on type burglar protection classified in resistance classification RC2 to RC6. These classifications were verified in test stands at authorized institutes with fully fitted and functional door elements. Even additional equipment like glazing and ventilation grilles was tested. Various lock combinations as well as the installations of various components are available.
The safety doors of classification RC2 to RC4 may be equipped with all suitable lock systems. As each door is manufactured individually on customer’s demands the installation of electronic access and monitoring systems is no problem with BUCHELE safety doors.
The bullet-proofed elements were tested in accordance with DIN EN 1522.
Basically all BUCHELE safety doors are reviewed and approved for installation in escape routes. This also applies for doors with glazing up to resistance classification RC4.
Technical data sheets
SINGLE LEAF
Fixed Glazing:
DOUBLE LEAF
What are the protection classes FB4 to FB7?
PLANE Line-Series: one- an two-wing-doors up to RC5
One thing is certain: Doors and gates by BUCHELE are safe. Manufactured under highest quality standards they keep their promises – and this is tested and certified. The door types are available with various features and are individually manufactured and planned depending on the application.
The safety doors by BUCHELE are certified in accordance with DIN EN 1627 – and provide depending on type burglar protection classified in resistance classification RC2 to RC6. These classifications were verified in test stands at authorized institutes with fully fitted and functional door elements. Even additional equipment like glazing and ventilation grilles were tested. Various lock combinations as well as the installation of various components are available.
The safety doors of classification RC2 to RC4 may be equipped with all suitable lock systems. As each door is manufactured individually on customer’s demands the installation of electronic access and monitoring systems is no problem with BUCHELE safety doors.
Technical data sheets
SINGLE LEAF
DOUBLE LEAF
What are the safety classes RC2 to RC5?